Tech:difference between Transformer Overcurrent Test And Temperature Rise Test2024-05-27



  Tech:difference between Transformer Overcurrent Test And Temperature Rise Test




What is the difference between ordinary high current generator and fully automatic temperature rise experiment system? Why is there such a big price difference between the two?


1. Overcurrent test


The overcurrent test is to verify the performance of the transformer under rated load and short-term overload conditions. In this test, the transformer should be able to withstand the rated current and short-term overload current for the required time without causing damage or failure. This kind of testing requires the use of special test equipment, such as high-voltage power supplies and current generators. This test can evaluate the performance of the transformer and prevent damage to the transformer and safety accidents caused by improper use before it is put into use.


2. Temperature rise test


The temperature rise test is to verify the operation of the transformer under rated load. During this test, the transformer should be able to withstand the rated load and not exceed the specified temperature range during operation. This test requires measuring the surface temperature of the transformer and recording it for comparison. If the operating temperature of the transformer is higher than the rated value, there may be a risk of damage and aging of the transformer.


3. The importance of the two tests


Overcurrent test and temperature rise test are both important means of performance testing of transformers. In the overcurrent test, the load characteristics of the transformer can be evaluated, as well as its ability to withstand rated current and short-term overload. In the temperature rise test, the safety performance of the transformer when operating under rated load can be verified, thereby preventing the transformer from burning out due to high temperature. In addition, these two tests are also to ensure that the transformer complies with national standards and safety regulations before being put into use.

To sum up, overcurrent test and temperature rise test are both commonly used transformer detection methods, but their purpose and test content are different. Through the correct use and implementation of these two tests, the normal operation of the transformer can be ensured, equipment protected, accidents reduced, and production efficiency improved.



 More information: 

Prduct, Video, News, Project,please kindly click the letters to view: 

Product: Primary Injection Tester, Temperature Rise Test, Big Current Generator

Tech:The Difference between Big Current Generator & Temperature Rise Test System

Tech:difference between Transformer Overcurrent Test And Temperature Rise Test

Vid: Power Frequency Hipot Test Set

News: Power Frequency Hipot Test Set

Project: Power Frequency Hipot Test Set





Product 

Picture

1589802837249208.jpg

HVSLQ Series Primary Current Injection Test Set

1590031478912992.jpg

HVTR-2500A Temperature Rise Test High Current Generator

Test 

Time

AC, or DC

A few minutes (eg 5 min)

Over 8 hours
Material
Need more copper and material
Component

1. Controller,

2. High current generator


1. Controller,

2. High current generator

3. Voltage Regulator